Hollow Fiber Imprinted Membranes Cellulose Acetate Based for Hemodialysis

Hollow Fiber Imprinted Membranes Cellulose Acetate Based for Hemodialysis

  • Muhammad Cholid Djunaidi Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia
  • Didik Setiyo Widodo Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia
  • Fathimatuz Zahra Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia
  • Nesti Dwi Maharani Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia
  • Heru Susanto Department of Chemical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Indonesia
  • Abdullah Malik Islam Filardli Department of Chemical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Indonesia

Abstract

ABSTRACT. One of the important roles of the kidneys is to excrete the residues of the body's metabolism, for example urea, uric acid, and creatinine. If these metabolic residues are allowed to accumulate, they can become toxic to the body, especially the kidneys. Hemodialysis has a process related to the disposal of metabolic residue particles in artificial kidneys which currently use a membrane that functions as a separator for metabolic residues with the patient's blood which is then circulated on its own. This study used Molecularly Imprinted Membrane (MIM) and Non-Imprinted Membrane (NIM) with cellulose and cellulose acetate polymers. The results of this study, the cellulose acetate MIM membrane has the highest value compared to other variation membranes, because the cellulose acetate MIM membrane is rich in –OH (hydroxyl) groups so that it makes the membrane more hydrophilic. The percentage of cellulose acetate MIM membrane porosity test was 86.75%, the percentage of water absorption test was 91.09%, the highest flux test value of cellulose acetate MIM membrane with demineralized water solution was 5.78 L/m2.hr. while the tensile test of the cellulose acetate NIM membrane was 12.141 N/mm2. The increase in the percentage value of porosity is directly proportional to the percentage value of water absorption and flux, but inversely proportional to the results of the tensile test which has a lower Young's modulus value compared to cellulose.


 


Keywords: Cellulose, Cellulose Acetate, Hollow Fiber, MIM, Hemodialysis.

Author Biographies

Muhammad Cholid Djunaidi, Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia

Department of Chemistry, Faculty of Science and Mathematics

Didik Setiyo Widodo, Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia

Department of Chemistry, Faculty of Science and Mathematics

Fathimatuz Zahra, Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia

Department of Chemistry, Faculty of Science and Mathematics

Nesti Dwi Maharani, Department of Chemistry, Faculty of Science and Mathematics, Diponegoro University, Semarang, 50275, Indonesia

Department of Chemistry, Faculty of Science and Mathematics

Heru Susanto, Department of Chemical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Indonesia

Department of Chemical Engineering, Faculty of Engineering

Abdullah Malik Islam Filardli, Department of Chemical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Indonesia

Department of Chemical Engineering, Faculty of Engineering

Published
2026-07-20
How to Cite
DJUNAIDI, Muhammad Cholid et al. Hollow Fiber Imprinted Membranes Cellulose Acetate Based for Hemodialysis. Molekul, [S.l.], v. 21, n. 2, p. 184-196, july 2026. ISSN 2503-0310. Available at: <https://jos.unsoed.ac.id/index.php/jm/article/view/7390>. Date accessed: 01 aug. 2026. doi: https://doi.org/10.20884/1.jm.2026.21.2.7390.
Section
Articles